Additions
 
 

Additions to Nonconforming Structures in Shoreland Areas

Existing nonconforming principal structures may be allowed one addition with a performance standard permit in accordance with the standards found in this Article, provided that no additions (not including a deck) have been added to the principal structure since January 1, 1982, and:

  • The original structure existed before setback requirements were established; or
  • The existing structure was approved through variance and not limited in size through the approval decision; or
  • The existing structure was approved through shoreline averaging; or
  • The existing structure was replaced with a performance standard permit.

Nonconforming Principal Structures

The general standards are as follows:

  • The existing principal structure (including deck) is setback from the shoreline a minimum of 25 feet or 25 percent of required shoreline setback, whichever is greater.
  • The height of the proposed addition, or completed principal structure, shall not exceed a total of:
    • 20 feet in height maximum if any part of the structure is within the shore impact zone.
    • 25 feet in height if all or any part of the structure is between the shore impact zone and the required setback.
  • The addition will not encroach upon the septic treatment system or expansion area.
  • The maximum allowable addition shall be determined by the following:
    • If a structure is located between zero and 25 feet from the shoreline, no additions are allowed.
    • If a structure is located between 25 feet and the shore impact zone, an addition total of 200 square feet is allowed.
    • If a structure is located outside the shore impact zone, an addition total of 400 square feet is allowed. The addition does not decrease the existing shoreline setback.
  • The property owner shall develop a stormwater runoff plan so runoff does not discharge directly into lakes, rivers, streams, wetlands, or adjacent properties.
  • The structure shall be screened from public waters by natural means.

Nonconforming Structures that Meet Shoreline Setback

A nonconforming structure that meets the shoreline setback, but does not meet property line, right-of-way, and/or road centerline setbacks may be expanded by land use permit without variance and shall be restricted in the following manner:

  • Additions may be in any direction except towards the nonconforming setback as long as the addition does not increase the existing nonconformity and it does not create a new nonconformity.
  • Structures that become nonconforming as a result of a change in functional road class may enlarge in a manner that does not exceed the road setback standards of the original classification.

Nonconforming Accessory Structures

A nonconforming accessory structure (other than water-oriented accessory structures) that does not meet shoreline setback may increase the structure height, but not expand the floor area or footprint, with a performance standard permit, without variance, and the following standards shall apply:

  • 20 feet in height maximum if all or part of the structure is within the shore impact zone.
  • 25 feet in height if the entire structure is between the shore impact zone and the required setback.


Contact